Heat pump NORDIS OPTIMUS PRO 190L HOP8WODU/HOP100/190IDU 8.3 / 8.4 kW
OPTIMUS PRO Split with Hot Water Tank
NØRDIS Optimus Pro Split air-to-water heat pumps are designed for heating and domestic hot water using energy from the outside air. The heat pump will ensure the home warm during the winter and provide hot water all year round in an ecological and economical way.
NØRDIS Optimus Pro Split series is based on DC technology. The technology optimizes the engine speed and ensures a comfortable amount of heat in the room with the lowest electricity consumption, even when the outdoor temperature drops to -25 ° C. Heat pumps can be combined with underfloor heating, radiators, fan coil systems.
Air-to-water heat pumps with an integrated hot water tank have two units of internal capacities and tanks. The latest technologies integrated into the devices ensure high performance and the lowest operating costs. The combination of heat pump equipment provides optimal possibilities in the process of heating, cooling and hot water preparation.
- Operates in heating mode when the outdoor temperature drops to -25 ° C.
- Extremely quiet – two quiet modes.
- Smart grid: heat pump adjusts the operation according to different electrical signals. Power consumption of the system can be automatically adjusted according to the peak and valley power to reduce the power consumption to a great extent.
- Integrated 190 l or 240 l stainless steel hot water tank.
- Modern touch-sensitive control panel.
- Integrated WiFi module for device control via smartphone.
- With the help of the Weather temperature curve function, the water temperature will automatically change as outside air temperature changes.
- Holiday away function: unit operates in heating mode and/or DHW mode with low water temperature to prevent water from freezing in the winter during the holiday outside. The user can pre-set, the disinfection mode before he returns home to make sure that germ-free water is available to be used when he returns.
TECHNICAL DATA:
Outdoor units | HOP8WODU | ||
---|---|---|---|
Heating A7W35 1 | Power | kW | 8,30 |
Energy consumption | kW | 1,60 | |
COP | 5,20 | ||
Heating A7W45 2 | Power | kW | 8,20 |
Energy consumption | kW | 2,08 | |
COP | 3,95 | ||
Heating A7W55 3 | Power | kW | 7,50 |
Energy consumption | kW | 2,36 | |
COP | 3,18 | ||
Heating A-7W35 4 | Power | kW | 7,10 |
Energy consumption | kW | 2,18 | |
COP | 3,25 | ||
Cooling A35W18 5 | Power | kW | 8,40 |
Energy consumption | kW | 1,66 | |
EER | 5,05 | ||
Cooling A35W7 6 | Power | kW | 7,40 |
Energy consumption | kW | 2,19 | |
EER | 3,38 | ||
Energy efficiency class7 | Water temperature 35°C | class | A+++ |
Water temperature 55°C | class | A++ | |
SCOP 7 | 35°C | 5,22 | |
55°C | 3,37 | ||
SEER 7 | 7°C | 5,83 | |
18°C | 8,95 | ||
Power supply | V/Ph/Hz | 220-240/1/50 | |
Rated power | W | 3300 | |
Rated current | A | 14,5 | |
Automatic switch | C16 ~1 | ||
Power cable | mm2 | 3x2,5 | |
Refrigerant | Type (GWP) | R32 (675) | |
Quantity in the device | kg | 1,65 | |
Refrigerant pipes | Liquid phase | mm (col) | 9,52 (3/8") |
Gas-phase | mm (col) | 15,88 (5/8") | |
Between the indoor and outdoor blocks | Height difference, max. | m | 20 |
Track length, min. | m | 3 | |
Track length, max. | m | 30 | |
Refrigerant replenishment | Quantity | g/m | 38 |
Pipe length | m | max.15 | |
Compressor | DC two rotor inverter | ||
Fan | DC electric motor | ||
Sound power level 8 | dB(A) | 59 | |
Sound pressure (at a distance of 1m) 9 | dB(A) | 46 | |
Sound pressure (1m away, silent mode) 9 | dB(A) | 41 | |
Dimensions (W x H x D) | mm | 1118×865×523 | |
Dimension of Package (W x H x D) | mm | 1190×970×560 | |
Net / Gross weight | kg | 78,5 / 92 | |
Outdoor operating temperature limits | Heating | °C | -25 ~ +35 |
Cooling | °C | -5 ~ +43 | |
Hot water preparation | °C | -25 ~ +43 |
Indoor units with built-in hot water tank | HOP100/190IDU | ||
---|---|---|---|
Efficiency class for hot potable water treatment (temperate zone) | class | A+ | |
COP | 3,02 | ||
Declared load profile | L | ||
Water tank capacity | Capacity | l | 190 |
Material | - | Stainless Steel, SUS 316L | |
Max water temperature | °C | 70 | |
Isolation | - | Poliuretanas | |
Built-in electric heater | kW | 3 | |
Power supply | V/Ph/Hz | 220-240/1/50 | |
Rated power | W | 3095 | |
Rated current | A | 13,5 | |
Power cable | mm2 | 3x2,5 | |
Communication cable, AWG18 shielded | mm2 | 2x0,75 | |
Sound power level | dB(A) | 40 | |
Sound pressure 9 | dB(A) | ND | |
Dimensions (W x H x D) | mm | 600x1683x600 | |
Dimension of Package (W x H x D) | mm | 653x1900x653 | |
Circulation pump | Type | DC, electronic | |
Maximum lifting height | m | 9 | |
Power | W | 5~90 | |
Minimum water flow | m3/h | 0,36 | |
Operating limits for water flow | m3/h | 0,4 ~ 2,1 | |
Heat exchanger | Plate, soldered | ||
Expansion tank | l | 8 | |
Refrigerant pipes | Liquid phase | mm (col) | 9,52 (3/8") |
Gas-phase | mm (col) | 15,88 (5/8") | |
Water pipe connection | Heating/cooling | R1" | |
Hot water preparation | R3/4" | ||
Net / Gross weight | kg | 139 / 154 | |
Supply water temperature | Heating | °C | +12 ~ +65 |
Cooling | °C | +5 ~ +30 | |
Hot water preparation | °C | +12 ~ +60 | |
Ambient temperature | °C | +5 ~ +35 | |
Water pressure in the heating/cooling system | bar | 1 ~ 2,5 | |
Water pressure in the hot water system (cold water) | bar | 1,5 ~ 3 |